Skip to Content
Category

Pressure switches, measuring instruments and flow monitors

Connection Length U max. I max. Maximum pressure Switching range Design Type Sequence
1/4" 90 mm AC140/DC200 V AC0,7/DC1 A 16 bar 0,5...3 l/min - FM10-14-N-3 33040001
3/4" 144,5 mm 250 V 3 A 10 bar 8...30 l/min - FM10-10-N-30 33040002
3/4" 144,5 mm 250 V 3 A 10 bar 8...30 l/min - FM10-34-N-30 33040003
3/4" 144,5 mm 250 V 3 A 10 bar 8...30 l/min - FM10-34-W-45 33040004
1/2" 114 mm 230 V 3 A 16 bar 4,5...12 l/min - FM10-12-N-12 33040005
1/2" 114 mm 230 V 3 A 16 bar 6...15 l/min - FM10-12-N-15 33040006
1/2" 114 mm 230 V 3 A 16 bar 1,6...4 l/min - FM10-12-N-4 33040007
1/4" 90 mm AC140/DC200 V AC0,7/DC1 A 16 bar 1...5 l/min - FM10-14-N-5 33040008
1/2" 114 mm 230 V 3 A 16 bar 4,5...12 l/min ATEX FM10-12-N-12-02 33040009
FM24-10-W-110-01
Flow monitors Series FM24; Viscosity compensated ...600mm²/s; Body Nickel plated brass; For any mounting position; Medium temperature Max. 120°C; Oil scale; Connection 1"; Indicating range 35...110L/min; Maximum pressure 250bar; Length 130mm; Without switching unit
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type
1" 130 mm NO contact 250 V 3 A 300 bar 15...45 l/min FM24-10-W-110-01
FM24-14-N-4-01
Flow monitors Series FM24; Viscosity compensated ...600mm²/s; Body Nickel plated brass; For any mounting position; Medium temperature Max. 120°C; Oil scale; Application: Monitoring of lubrication; Switch unit Wechsler; Connection 1/4"; Switching range 1...4L/min; Maximum pressure 250bar; U max. 250V; I max. 1,5A; Length 130mm
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type
1/4" 130 mm Change-over contact 250 V 1,5 A 250 bar 1...4 l/min FM24-14-N-4-01
FM24-10-W-45
Flow monitors Series FM24; Viscosity compensated ...600mm²/s; Body Stainless steel 1.4571; For any mounting position; Medium temperature Max. 120°C; Oil scale; Application: Monitoring of lubrication; Switch unit Schließer; Connection 1"; Switching range 15...45L/min; Maximum pressure 300bar; U max. 250V; I max. 3A; Length 130mm
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type
1" 130 mm NO contact 250 V 3 A 300 bar 15...45 l/min FM24-10-W-45
Flow monitors Series FM24

Flow monitors Series FM24

Viscosity compensated ...600mm²/s; Body Nickel plated brass; For any mounting position; Medium temperature Max. 120°C; Oil scale; Application: Monitoring of lubrication

Grundversion
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type Sequence
1" 130 mm NO contact 250 V 3 A 250 bar 30...110 l/min FM24-10-N-110-04 33060001
1" 130 mm Change-over contact 250 V 1,5 A - 1...4 l/min FM24-10-N-4-01 33060002
FM24-10-W-60
Flow monitors Series FM24; Viscosity compensated ...600mm²/s; Body Stainless steel 1.4571; For any mounting position; Medium temperature Max. 120°C; Oil scale; Application: Monitoring of lubrication; Switch unit Schließer; Connection 1"; Switching range 20...60L/min; Maximum pressure 300bar; U max. 250V; I max. 3A; Length 130mm
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type
1" 130 mm NO contact 250 V 3 A 300 bar 20...60 l/min FM24-10-W-60
FM24-10-N-30-02
Flow monitors Series FM24; Viscosity compensated ...600mm²/s; Body Nickel plated brass; For any mounting position; Medium temperature Max. 120°C; Oil scale; Application: Monitoring of lubrication; Switch unit Wechsler (SPS); Connection 1"; Switching range 10...30L/min; Maximum pressure 250bar; U max. 250V; I max. 1A; For SPS; Length 130mm
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type
1" 130 mm Change-over contact 250 V 1,5 A - 10...30 l/min FM24-10-N-30-02
FM24-12-W-1,5
Flow monitors Series FM24; Viscosity compensated ...600mm²/s; Body Stainless steel 1.4571; For any mounting position; Medium temperature Max. 120°C; Oil scale; Application: Monitoring of lubrication; Switch unit Schließer; Connection 1/2"; Switching range 0,5...1,5L/min; Maximum pressure 300bar; U max. 250V; I max. 3A; Length 152mm
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type
1/2" 152 mm NO contact 250 V 3 A 300 bar 0,5...1,5 l/min FM24-12-W-1,5
FM24-10-N-4-03
flow monitors series FM24; viscosity compensated ...600mm²/s; body nickel plated brass; for any mounting position; medium temperature max. 120°C; oil scale; application: monitoring of lubrication; switch unit change-over contact; connection G1"; switching range 1...4l/min; maximum pressure 250bar; U max. 250V; I max. 1,5A; length 130mm
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type
1" 130 mm Change-over contact 250 V 1,5 A 250 bar 1...4 l/min FM24-10-N-4-03
FM24-12-W-4
Flow monitors Series FM24; Viscosity compensated ...600mm²/s; Body Stainless steel 1.4571; For any mounting position; Medium temperature Max. 120°C; Oil scale; Application: Monitoring of lubrication; Switch unit Schließer; Connection 1/2"; Switching range 1...4L/min; Maximum pressure 300bar; U max. 250V; I max. 3A; Length 152mm
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type
1/2" 152 mm NO contact 250 V 3 A 300 bar 1...4 l/min FM24-12-W-4
FM24-10-N-30-01
Flow monitors Series FM24; Viscosity compensated ...600mm²/s; Body Nickel plated brass; For any mounting position; Medium temperature Max. 120°C; Oil scale; Application: Monitoring of lubrication; Switch unit Wechsler; Connection 1"; Switching range 10...30L/min; Maximum pressure 250bar; U max. 250V; I max. 1,5A; Length 130mm
Connection Length Switch unit U max. I max. Maximum pressure Switching range Type
1" 130 mm Change-over contact 250 V 1,5 A 250 bar 10...30 l/min FM24-10-N-30-01