Skip to Content
Search
Your Cart
Loading...
Categories
Loading...
Home Search 0 Wishlist
Category

Other materiales - Special armatures

SK-RV30-15-15-15/25
Seal kit for RV30-15-15-15/25
CVT3-20-XX-XXX
3/2-way-coaxial valve; Directly operated; G3/4"; 0...16bar; 24VDC; DN20; NC; Body: Brass; Medium: Emulsion; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED (B.); Incl. inspection certificate 3.1; With manual operation; TÜV design; ATEX Areas 1, 21: II 2 G Ex mb e II T4 / II 2 D Ex tD A21 IP65 T130 °C And II 2G Ex h IIC T4 Gb / II 2D Ex h IIIC T130°C Db
ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version
CVT3-25-XX-XXX
3/2-way-coaxial valve; Directly operated; G1"; 0...16bar; 24VDC; DN25; NC; Body: Brass; Medium: Emulsion; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED (B.); Incl. inspection certificate 3.1; With manual operation; TÜV design; ATEX Areas 1, 21: II 2 G Ex mb e II T4 / II 2 D Ex tD A21 IP65 T130 °C And II 2G Ex h IIC T4 Gb / II 2D Ex h IIIC T130°C Db
ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version
CVT-32-XX-XXX
2/2-way coaxial valve; Directly operated; G11/4"; 0...16bar; 24VDC; DN32; NC; Body: Brass; Medium: Emulsion; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED (B.); Incl. inspection certificate 3.1; With manual operation; ATEX Areas 1, 21: II 2 G Ex mb e II T4 / II 2 D Ex tD A21 IP65 T130 °C And II 2G Ex h IIC T4 Gb / II 2D Ex h IIIC T130°C Db
ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version
CVT3-32-XX-XXX
3/2-way-coaxial valve; Directly operated; G11/4"; 0...16bar; 24VDC; DN32; NC; Body: Brass; Medium: Emulsion; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED (B.); Incl. inspection certificate 3.1; With manual operation; ATEX Areas 1, 21: II 2 G Ex mb e II T4 / II 2 D Ex tD A21 IP65 T130 °C And II 2G Ex h IIC T4 Gb / II 2D Ex h IIIC T130°C Db
ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version
CVT3-40-XX-XXX
3/2-way-coaxial valve; Directly operated; G11/2"; 0...16bar; 24VDC; DN40; NC; Body: Brass; Medium: Emulsion; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED (B.); Incl. inspection certificate 3.1; With manual operation; ATEX Areas 1, 21: II 2 G Ex mb e II T4 / II 2 D Ex tD A21 IP65 T130 °C And II 2G Ex h IIC T4 Gb / II 2D Ex h IIIC T130°C Db
ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version
CVT3-50-XX-XXX
3/2-way-coaxial valve; Directly operated; G2"; 0...16bar; 24VDC; DN50; NC; Body: Brass; Medium: Emulsion; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED (B.); Incl. inspection certificate 3.1; With manual operation; ATEX Areas 1, 21: II 2 G Ex mb e II T4 / II 2 D Ex tD A21 IP65 T130 °C And II 2G Ex h IIC T4 Gb / II 2D Ex h IIIC T130°C Db
ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version
CVT-40-XX-XXX
2/2-way coaxial valve; Directly operated; G11/2"; 0...16bar; 24VDC; DN40; NC; Body: Brass; Medium: Emulsion; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED (B.); Incl. inspection certificate 3.1; With manual operation; ATEX Areas 1, 21: II 2 G Ex mb e II T4 / II 2 D Ex tD A21 IP65 T130 °C And II 2G Ex h IIC T4 Gb / II 2D Ex h IIIC T130°C Db
ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version
CVT-50-XX-XXX
2/2-way coaxial valve; Directly operated; G2"; 0...16bar; 24VDC; DN50; NC; Body: Brass; Medium: Emulsion; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED (B.); Incl. inspection certificate 3.1; With manual operation; ATEX Areas 1, 21: II 2 G Ex mb e II T4 / II 2 D Ex tD A21 IP65 T130 °C And II 2G Ex h IIC T4 Gb / II 2D Ex h IIIC T130°C Db
ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version
CVF-65-XX-XXX
2/2-way coaxial valve; Directly operated; Flange DN65; PN16; 0...16bar; 24VDC; NC; Body: Stainless steel; Medium: Water; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. 2 inductive limit switches OPEN/CLOSED (B.); Incl. inspection certificate 3.1;
ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version
CVT-80-XX-XXX
2/2-way coaxial valve; Directly operated; Flange DN80; PN16; 0...16bar; 24VDC; NC; Body: Stainless steel; Medium: Water; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. 2 inductive limit switches OPEN/CLOSED (B.); Incl. inspection certificate 3.1;
ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version
CVTDH-XX-XX-XXX
Coax-2/2-way-lateral valve; Directly operated; G1/2"; 0...16bar; 24VDC; DN15; NC; Body: Brass; Medium: Emulsion; Incl. LED; Special seals; Incl. 2 inductive limit switches OPEN/CLOSED; Incl. inspection certificate 3.1; Incl. certificate for vacuum; ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version
CVTE-10-NC-003
2/2-way coaxial valve; G1/2"; 0…40bar; DN10; NC; Externally controlled; Body: Brass; Medium: Air/Helium; Incl. 1 inductive limit switch (I) For closed-position; Incl. certificate for vacuum; Special version
CVTE3-P-XX-XX-XXX
3/2-way-coaxial valve; Externally controlled; G1/2"; 0...16bar; 24VDC, DN15; NC; Body: Brass; Medium: Emulsion; Incl. 5/2-way pilot valve; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED; Incl. inspection certificate 3.1; With manual operation; Incl. certificate for vacuum; Special version
CVTE3-XX-XX-XXX
3/2-way-coaxial valve; Externally controlled; G1/2"; 0...16bar; 24VDC, DN15; NC; Body: Brass; Medium: Emulsion; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED; Incl. inspection certificate 3.1; With manual operation; Incl. certificate for vacuum; ATEX II 2G Ex h IIC T6..T3 Gb And II 2D Ex h IIIC T-40°C...+195°C Db; Special version
CVTEH-XX-XX-XXX
2/2-way coaxial valve; Externally controlled; G1/2"; 0...200bar; DN15; NC; Body: Brass; Medium: Emulsion; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED; Incl. inspection certificate 3.1; With manual operation; Incl. certificate for vacuum; ATEX II 2G Ex h IIC T6..T3 Gb And II 2D Ex h IIIC T-40°C...+195°C Db; Special version
CVTE-P-MASTER
2/2-way coaxial valve; Externally controlled; G1/2"; 0...16bar; 24VDC, DN15; NC; Body: Brass; Medium: Emulsion; Incl. 5/2-way pilot valve; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED; Incl. inspection certificate 3.1; With manual operation; Incl. certificate for vacuum; Special version