Skip to Content
Search
Your Cart
Loading...
Categories
Loading...
Home Search 0 Wishlist
Category

Special armatures

5MB-MK1015NC-547093
5-way module consisting of: 1x2/2-way coaxial valve, MK10NC, G 1/2" 0-16 bar, 24VDC, DN 10, NC, direct-acting body: brass, medium: emulsion, incl. LED, 4x2/2-way coaxial valve, MK15NC, G 1/2" 0-16 bar, 24VDC, DN 15, NC, direct-acting body: brass, medium: emulsion, incl. LED, module: aluminium, separating plate, adapter cover additional thread in end cover G1"
FK50NC-553048
2/2-way coaxial valve; Flange PN16, DN50; 0...16bar; 230VAC; NC; Directly operated; Body: Zinc plated steel; Medium: Oil; Incl. LED; Special seals;Incl. 2 inductive NAMUR limit switches OPEN/CLOSED (B); Special version
SG04-80-UWF80-01
Sliding gate-shut off valve Pneumatically operated Type SG04, DN80; PN10/40; NC; Body: Zinc plated steel, Fixed disc 1.4571 Coated; Sliding disc SFC; Kvs-value 40 (40%); Characteristic linear; Piston actuator 80mm
EP0S11PEZ
Mounted I/P positioner for double-acting actuator, Sipart PS2, input 4-20mA, incl. 2 inductive limit switches P&F SJ-2SN (switching amplifier required), position feedback 4-20mA
CVFF-80-NC-001
2/2-way coaxial valve; Externally controlled; Flange DN80 PN40; 0...40bar; NC; Body: Special hartcoatiert; Medium: Biogas -10...+60°C; Special seals; Namur control port; ATEX Ex II 2G Ex h IIC T-10°C…+60°C Gb; Ex II 2D Ex h IIIC T-10°C…+60°C Db; Special version
CVT-40-NC-027
2/2-way coaxial valve; Directly operated; Connection G2"; DN40mm; 0...40bar; 24VDC; NC; Body: Stainless steel; Medium: Propane/Butane -20...+30°C; Special seals; Incl. 2 inductive limit switches OPEN/CLOSED (B.); ATEX CE Ex nA II T3 / CE Ex tc IIIC T195°C; Ex II 3G Ex h IIC T3 Gc; Ex II 3D Ex h IIIC T195°C Dc; Special version
CVT-40-NC-028
2/2-way coaxial valve; Directly operated; Connection G2"; DN40mm; 0...40bar; 24VDC; NC; Body: Stainless steel; Medium: Dimethyl ether -20...+30°C; Special seals; Incl. 2 inductive limit switches OPEN/CLOSED (B.); ATEX CE Ex nA II T3 / CE Ex tc IIIC T195°C; Ex II 3G Ex h IIC T3 Gc; Ex II 3D Ex h IIIC T195°C Dc; Special version
CV4TE-P-15-NC-002
4-fold-Module block Consists of 4 Pieces CVMTE-P-15-NC-003; 2/2-way coaxial valve; G1"; 0...16bar; 24VDC, DN15; NC; Externally controlled; Body: Brass; Medium: Emulsion; Incl. 5/2-way pilot valve; Incl. LED; End plate With additional thread; Incl. mounting bracket; Special version
CVFE-P-50-NC-002
2/2-way coaxial valve; Flange DN50; PN63; 0...63bar; 24VDC; NC; Externally controlled; Body: Steel nickel plated; Medium: Condensate 60°C; Incl. 5/2-way pilot valve; Incl. LED; Special seals; Incl. 2 inductive limit switches OPEN/CLOSED; Incl. inspection certificate 3.1; Special version
CV4T-10-NC-009
4-fold-module block consists of 4 pieces CVMT-10-NC-###; 2/2-way coaxial valve; directly operated; connection: G3/8"; 0…16bar; 24VDC; DN10; NC; body: stainless steel; medium: water/1% Peracetic acid; incl. LED; special seals; material module block stainless steel; inlet module block G1"; module block 4xG3/8"; special version
CVTEH-15-N0-006
2/2-way coaxial valve; Externally controlledG1/2"; 0…200bar; DN15; NO; Body: Stainless steel; Medium: Gas-Turbine oil -20...+45°C; Incl. 2 inductive limit switches (B.); Special seals; Special version
CVTEH-15-N0-007
2/2-way coaxial valve; Externally controlledG1/2"; 0…200bar; DN15; NO; Body: Stainless steel; Medium: Demineralized water -20...+45°C; Incl. 2 inductive limit switches (B.); Special seals; Special version
SG09-25-UWN1253-02
Control valve Type SG09; DN25; ANSI600; NC; Material: Zinc plated steel; Fixed disc STN2; Sliding disc STN2; Kvs-value 0,62 (6,3%); Characteristic Linear; Diaphragm actuator 125cm², Incl. Coupler
CVTE3-25-NC-008
3/2-way-coaxial valve; Externally controlled; Connection SAE 1 5/8-12; 0...100bar; DN25; NC; Body: Stainless steel; Medium: Coolant; Mounting bracket; Special version
CVCRQ-20-001
Position control valve; G1"; 0...63bar; DN20; 24VDC; Setpoint value input 0...10V; Directly operated; Body: Brass; Medium: Emulsion; Special version
CVCRQ-20-003
Coax-Position control valve; G3/4"; 0…63bar; DN20; 24VDC; Setpoint value input 4...20mA; Directly operated With integrated 3-point control; Body: Brass; Medium: Tap water ; Special version
CVCRQ-20-005
Coax-Control valve; Directly operated; G1"; 0...100 Bar; 24VDC; DN20; Body: Brass; Medium: Coolant; Setpoint value input 0-10V; With integrated 3-point control; Electrical connection M12x1; Special version
CVCRQ-20-006
Coax-Control valve; Directly operated; G1"; 0...64bar; 24VDC; DN20; Body: Brass; Medium: Emulsion; Setpoint value input 0-10V; With integrated 3-point control; Electrical connection M12x1; Special version
CVCDH-P-15-NC-006
Coax-2/2-way-lateral valve; Externally controlled; G1/2"; 0...500bar; 24VDC; DN15; NC; Body: Stainless steel; Medium: Hydrogen; Special seals; Incl. certificate for vacuum; Incl. 5/2-way pilot valve; Incl. LED; Special version
RMQ20-522406
Coax position control valve, G1" 0...64bar, DN20, 24VDC, setpoint input 4...20mA direct operated, with integrated 3-point control Body: brass, Medium: emulsion incl. circular connector to DIN 40040, 5-pin, M12x1