Skip to Content
Category

Pressure switches, measuring instruments and flow monitors

PT02-14N-600V-420
Pressure transmitter; Body, Wetted parts Stainless steel 1.4404; Pressure sensor Stainless steel AISI 316L; Seal NBR; Outlet signal 4...20 mA Proportional to applied pressure; Male thread 1/4"; Accuracy 1% of full pressure range; Measuring range -0,6...0 bar
PT02-14NN-1000-420
Pressure transmitter; Body, Wetted parts Stainless steel 1.4404; Pressure sensor Stainless steel AISI 316L; Seal NBR; Outlet signal 4...20 mA Proportional to applied pressure; Male thread 1/4" NPT; Accuracy 1% of full pressure range; Measuring range 0...1000bar
PT02-14N-V-420
Pressure transmitter; Body, Wetted parts Stainless steel 1.4404; Outlet signal 4...20 mA Proportional to applied pressure; Male thread 1/4"; Accuracy 1% of full pressure range; Measuring range -1...0bar
PT02-14V-016-420
Pressure transmitter; Body, Wetted parts Stainless steel 1.4404; Outlet signal 4...20 mA Proportional to applied pressure; Male thread 1/4"; Measuring range 0...16bar; Medium temperature -30 To +100°C
PT02-D38-R-V159-0545
Pressure transmitter; Body, Wetted parts Stainless steel 1.4404; Pressure sensor Stainless steel AISI 316L; Seal Copper; Outlet signal 0,5...4,5V; Proportional to applied pressure; Thread G3/8" B EN837; Measuring range -1...+159bar; Connector DIN EN 175301-803 A
PT02-D38-R-V59-0545
Pressure transmitter; Body, Wetted parts Stainless steel 1.4404; Pressure sensor Stainless steel AISI 316L; Seal Copper; Outlet signal 0,5...4,5V; Proportional to applied pressure; Male thread G3/8" B EN837; Measuring range -1...+59bar; Connector DIN EN 175301-803 A
PT04-12-006-010
Pressure transmitter; Body 1.4571; Wetted parts Stainless steel 1.4404; Seal Copper; Outlet signal 0...10V; Proportional to applied pressure; Accuracy 0,25% of full pressure range; Male thread G 1/2"; Measuring range 0...6bar
PT04-12-200V200-420
Pressure transmitter; Body, Wetted parts Stainless steel 1.4404; Outlet signal 4...20 mA Proportional to applied pressure; Accuracy 0,5% of full pressure range; Male thread G 1/2"; Measuring range -200...+200mbar; Incl. Zero position adjustment
PT04-12V-016-420-01
Pressure transmitter; Body, Wetted parts Stainless steel 1.4404; Pressure sensor Stainless steel AISI 316L; Seal FKM; Outlet signal 4...20 mA Proportional to applied pressure; Male thread 1/2"; Accuracy 1% of full pressure range; Measuring range 0...16bar; Free of oil and grease for oxygen
PT04-14N-040-420-01
Pressure transmitter; Body, Wetted parts Stainless steel 1.4404; Outlet signal 4...20 mA Proportional to applied pressure; Accuracy 0,5% of full pressure range; Male thread 1/4"NPT; Measuring range 0...40bar; Incl. Digital inidicator, attach type
PT04-14N-040-420-02
Pressure transmitter; Body, Wetted parts Stainless steel 1.4404; Outlet signal 4...20 mA Proportional to applied pressure; Accuracy 0,5% of full pressure range; Male thread 1/4"NPT; Measuring range 0...40bar; Incl. Digital inidicator, attach type
PT04-14N-V5-420-01
Pressure transmitter; Body, Wetted parts Stainless steel 1.4404; Outlet signal 4...20 mA Proportional to applied pressure; Accuracy 0,5% of full pressure range; Male thread G 1/4"; Measuring range -1...+5bar; Electrical connection M12x1 (4-pin)
PT04-14N-V9-420-01
Pressure transmitter; Body, Wetted parts Stainless steel 1.4404; Outlet signal 4...20 mA Proportional to applied pressure; Accuracy 0,5% of full pressure range; Male thread G 1/4"; Measuring range -1...+9bar; Electrical connection M12x1 (4-pin)
PT05-12V-V025-420
Pressure transmitter; Body, Wetted parts Stainless steel 1.4404; Outlet signal 4...20 mA Proportional to applied pressure; Male thread 1/2"; Accuracy 0,5% of full pressure range; Electrical connection Connector DIN EN 175301-803; Measuring range -1...25bar
PT06-14V-V-420-01
Pressure transmitter; Body, Wetted parts Stainless steel 1.4305; Outlet signal 4...20 mA Proportional to applied pressure; Male thread 1/4"; Accuracy 1% of full pressure range; Measuring range -1...0bar; Voltage 10...33VDC; Electrical connection Connector DIN EN 175301-803; Better overpressure protection
PT08-12N-004-420
Pressure transmitter; Body, Wetted parts Stainless steel 1.4571; Outlet signal 4...20 mA Proportional to applied pressure; Male thread 1/2"; Accuracy 0,5% of full pressure range; Measuring range 0...4bar
PT08-14N-040-020
Pressure transmitter; Body, Wetted parts Stainless steel 1.4571; Seal NBR; Outlet signal 0...20 mA Proportional to applied pressure; Male thread 1/4"; Accuracy 0,5% of full pressure range; Measuring range 0...40bar
PT09-14-006-420-01
Pressure transmitter; Body, Wetted parts Stainless steel 1.4571; Outlet signal 4...20 mA Proportional to applied pressure; Male thread 1/4"; Accuracy 0,5% of full pressure range; Electrical connection Connector M12x1 4-pin; Measuring range 0...6bar; ATEX- II 1/2G Ex ia IIC T4/T5/T6 Ga/Gb
PT09-14-010-420-01
Pressure transmitter; Body, Wetted parts Stainless steel 1.4571; Outlet signal 4...20 mA Proportional to applied pressure; Male thread 1/4"; Accuracy 0,5% of full pressure range; Electrical connection Connector M12x1 4-pin IEC 61076-2-101 A-COD; Measuring range 0...10bar; ATEX- II 1/2G Ex ia IIC T4/T5/T6 Ga/Gb